Product Details:
Payment & Shipping Terms:
|
Frequency: | 433/868/915MHz | Power Output: | 1W |
---|---|---|---|
Distance: | 2-3km/5km | Input: | 8 Digital Inputs |
Output: | 8 Relay Outputs | Protocol: | Modbus RTU |
High Light: | 8DI 8DO Wireless ON OFF Module,1W Wireless ON OFF Module,4G Wireless Modbus RTU |
8DI 8DO Wireless ON OFF Module 433MHz / 868MHz / 915MHz 4G Wireless Modbus RTU
1. General Introduction
LS-RDIO0808 wireless RTU has 8 digital input, 8 relay putput.
We have different types to meet your different control distance requirements.
Within 2km, you could use our RF type,
Around 5km, you could use 5W version or Lora type
If you wants to control longer distance, you could use 4G type wireless I/O
2. Application Field
LS-RDIO series I/O module is widely used in industry automation like factory central data process, pump control, oil monitoring, mining machinery, environment monitoring equipments, lifting devices, robots control, filling machine, mixing equipments, logistic line, AGV etc.
3. Parameter
Parameter | |
Power output: | 1W or 100mW version |
Power supply: | 9V-30V (usually choose 24V DC or 12V DC) |
Control distance: | 3km or (1km version) |
Baud rate: | 1200bps |
Receiving sensibility: | -123dBm@1200bps, -118dbm(9600bps) |
Networking | |
Networking: | Point to point and point to multipoint |
Port Description | |
Input: | 8 active DI (passive customized) |
Output: | 8 relay passive outputs, |
Communication port | RS485 (wireless RS485 customize) |
Current | |
Transmit current: | <600mA (or 100mA version) |
Receiving current: | <50mA (or 20mA version) |
General | |
Frequency: | 433MHz, 400, 450, 470 or other band |
Channel No: | 16 channels,can change via DIP switch |
Physical Properties | |
Dimension: | 145×90×40(mm) |
Antenna Connector: | SMA,vehicle antenna with 1.5m cable |
Temperature: | -35℃~+75℃( industrial) |
Mounting method: | Standard 3.5 inch industrial guild rail |
4. How to use wireless I/O
5. Application diagram examples
1) Point to point control
Remarks:
Module A | Module B | Input and Output Correspondence |
A(DI1-DI8) | B(DO1-DO8) | DI1-DI8 of A to control DO1-DO8 of B respectively |
A(DO1-DO8) | B(DI1-DI8) | DO1-DO8 of A is controlled by DI1-DI8 of B respectively |
Notes: A and B should use the same channel |
2) One master to control 2 slaves
Remarks:
Master Module | Slave Module | Input and Output Correspondence |
A(DI1-DI4) | B1(DO1-DO4) | DI1-DI4 of A control DO1-DO4 of B1 respectively |
A(DI5-DI8) | B2(DO1-DO4) | DI5-DI8 of A control DO1-DO4 of B2 respectively |
A(DO1-DO4) | B1(DI1-DI4) | DO1-DO4 of A is controlled by DI1-DI4 of B1 |
A(DO5-DO8) | B2(DI1-DI4) | DO5-DO8 of A is controlled by DI1-DI4 of B2 |
Notes: A and B should use the same channel |
3) One master to control 4 slaves
Remarks:
Master | Slave | Input and Output Correspondence |
A(DI1-DI2) | B1(DO1-DO2) | DI1-DI2 of A control DO1-DO2 of B1 |
A(DI3-DI4) | B2(DO1-DO2) | DI3-DI4 of A control DO1-DO2 of B2 |
A(DI5-DI6) | B3(DO1-DO2) | DI5-DI6 of A control DO1-DO2 of B3 |
A(DI7-DI8) | B4(DO1-DO2) | DI7-DI8 of A control DO1-DO2 of B4 |
A(DO1-DO2) | B1(DI1-DI2) | DO1-DO2 of A controlled by DI1-DI2 of B |
A(DO3-DO4) | B2(DI1-DI2) | DO3-DO4 of A controlled by DI1-DI2 of B2 |
A(DO5-DO6) | B3(DI1-DI2) | DO5-DO6 of A controlled by DI1-DI2 of B3 |
A(DO7-DO8) | B4(DI1-DI2) | DO7-DO8 of A controlled by DI1-DI2 of B4 |
Notes: A and B should use the same channel |
4) One master to 8 salves
Remarks:
Master | Salve | Input and control correspondence |
A(DI1) | B1(DO1) | DI1 of A control DO1 of B1 |
A(DI2) | B2(DO1) | DI2 of A control DO1 of B2 |
A(DI3) | B3(DO1) | DI3 of A control DO1 of B3 |
A(DI4) | B4(DO1) | DI4of A control DO1 of B4 |
A(DI5) | B5(DO1) | DI5 of A control DO1 of B5 |
A(DI6) | B6(DO1) | DI6 of A control DO1 of B6 |
A(DI7) | B7(DO1) | DI7 of A control DO1 of B7 |
A(DI8) | B8(DO1) | DI8 of A control DO1 of B8 |
A(DO1) | B1(DI1) | DO1 of A is controlled by DI1 of B1 |
A(DO8) | B8(DI1) | DO8 of A is controlled by DI1 of B8 |
Note: module A and B should use the same channel; |
5) To communicate with PC/PLC
Contact Person: Sunny
Tel: +8613826574847
433MHz RF Data Module 100mW Wireless Data Transfer 1km RS232 RS485 TTL
433MHz RF Data Module , Wireless Rf Transmitter 2KM Wireless Transceiver Module For AMR
100mW Wireless Data Module 433MHz Wireless Data Transfer For 500m Serial Data
100mW Wireless Data Module RS232 Interface 500m Wireless Data Transmission 433MHz
Intelligent Wireless Irrigation Controller , Irrigation Program Wireless Sprinkler Controller
9-12V Wireless Irrigation Controller Wire Solution Sub Decode Board 128 Station Decode Board
Underground Internet Controlled Sprinkler System Intelligent For Pulse Drive Solenoid
433MHz Wireless irrigation System Solenoid Valve On-Off Control
433MHz Wireless Tank Level Monitoring System HMI wireless control pump ON OFF 2km
2DI2DO PLC Wireless Pump Control / Relay / Valve 433MHz Wireless ON OFF Control
Pump ON-OFF Control System According the Float Switch High Or Low Level
10DI 10DO Wireless Modbus RTU 10 Digital Inputs 10 Relay Outputs 2km Wireless ON OFF Control