Input: | 2AI | Type: | 4-20mA Or 0-5V |
---|---|---|---|
Frequency: | 433MHz/868MHz/915MHz | Distance: | 2km LOS Or More |
High Light: | wireless signal transfer,remote i o module |
2-3km Wireless I O Module 4-20mA Wireless Signal Transmission 2 Channels AI 0-5v
Introduction
LS-RAI02 Modbus RTU is a 1W I/O module, 2 analog inputs, 1 RS485 (wireless RS485 customizes). Wireless control 2km-3km. Use for sensor data wireless collection.
Character:
Transparent I/O System
Not need internet, no third party cell, no monthly fees
You have full control over your own carrier
Real time status feedback from the remote site
Fast installation and easy setup
General introduction
LS-RAIO Modbus RTU is an industrial controller designed by Lensen Technology. It supports point to point, point to multi-points wireless AI, AO (4-20mA or 0-5V or 0-10V signal) collection and control. This wireless RTU has the advantage of easy installation, no program required, no communication fee. It is reliable and cost-effective substitution for rail signal cable and slip ring signal wire.
This series we have 2AI, 2AO, 4AI and 4AO 4 items. Power output we have 2 versions, one is 100mW for 600m LOS control distance, and another one is 1W for 3km LOS control distance. For longer control distance, we also have other higher power output radio modem to configure.
Application area
LS-RAIO series are widely used for sensor’s signal wireless collection and meters’ data wireless transmission, kinds of sensors data like liquid level, flow, pressure, weight, temperature, humidity, vibration, distance are applied. So wireless AI, AO modules are widely used in oil, chemical industry, metallurgy, water treatment, environmental protection, air conditioning, medicine and other fields.
Frequency | 433MHz or 450MHz or 470MHz |
Power output | 1W |
Products | 2AI |
Input type | 4-20mA or 0-5V or 0-10V |
Output type | 4-20mA or 0-5V or 0-10V |
Resolution ratio | 24 bit |
Accuracy | ±0.02% |
Power supply | 9-36V DC usually use 24V DC |
Interface | RS-485 |
Channel No. | 16ch default, can program via DIP switch |
Antenna | Sucker antenna with 1.5m cable |
Working temperature | -35 °C ~ +75 °C industrial |
Working humidity | 10%-90% relative humidity, no condensation |
Dimension | 115×90×40(mm) |
Fix way | Standard 3.5 inch industrial DIN guild rail |
About the DIP switch
1) Outer(right side) DIP 1-4 are used for channel setting. Please check the following definition:
Channel No. | DIP Setting | Channel No. | DIP Setting | Channel No. | DIP setting | Channel No. | DIP setting |
1 |
1234 |
2 |
1234 |
3 |
1234 |
4 |
1234 |
5 |
1234 |
6 |
1234 |
7 |
1234 |
8 |
1234 |
2) Outer(right side) DIP 5-8 are used for mode setting. Please check the following definition
DIP | Status | Function | Remarks |
5 | OFF | With feedback | |
ON | No feedback mode | remote side DI, this side only DO | |
6,7 | OFF,OFF | 1 to 1 control |
Master set ID to X, Slave module’s ID set to X (ie. master ID1, slave ID1. remember set ID the same) |
6,7 | ON,OFF | 1 to 2 slaves control |
Master set to ID1, 2 slave modules’ ID set to 1 and 2 respectively |
6,7 | OFF,ON | 1 to 4 slaves control |
Master set to ID 1, 4 salve modules’ ID set to 1, 2, 3 and 4 respectively |
8 | OFF | Slave mode | |
ON | Master mode |
Application diagram
1. Point to point control application
2. Point to multipoint application
3. Modbus RS485 wireless communication